Steps needed before using SHS data spaces in TABEX/4 Windows

How are SHS data spaces implemented in TABEX/4 Windows?

SHS data spaces are implemented as shared memory segments using Windows file mapping objects.

The following configurations must be set so that the TABEX/4 services and programs can process these global system objects in newer Windows versions.

Windows permissions

The user IDs under which the TABEX/4 services, batch and console programs run, must have the Windows permission "create global objects".

 

fig. generation of global objects

TABEX/4 system parameters

In the TABEX/4 system parameters (file boiparam.txt in the TABEX/4 subdirectory "sys") the entry WINOBJ must have the prefix "Global\", so that objects are addressed in the global namespace and not objects in the own session.

The required entry may already be listed within comment brackets in the parameter file.

In this case, the desired entry shall be activated by removing the comment brackets. The previous entry shall be deactivated by adding the comment brackets, so that it becomes inactive.

Otherwise, the entry must be changed (if it already exists) or added, if it does not yet exist.

fig. boiparam.txt

Migration Packages

BOI GmbH offers migration packages for the table management systems SPITAB, TABSYS and VTAS.

 

» Migrations Packages

Success Stories

AirPlus has been using TABEX for 20 years.

Now TABEX/4 JAVA APPLICATION ENGINE has additionally been launched for audit-proof logging of the business processes by Java applications.

 

» read this success story

» more success stories